Hypertherm V9 Series Phoenix Rev.11 Bedienungsanleitung Seite 274

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 294
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 273
274 Phoenix 9.76.0 Installation and Setup Manual 806410
15 Oxyfuel Application
2. Select the gas channel and assign an analog output and maximum pressure for it. The channels are listed in groups.
Each channel in each group should be selected and matched with an analog output. The CNC transfers these
channels and pressures to the Oxyfuel Process screen.
Setting gas pressures from the CNC
You can adjust the pressures on the Oxyfuel Process screen. Each pressure has a ramp-up time. The oxyfuel cut chart
provides the starting set of values.
Oxyfuel torch pressures Analog outputs to assign
Standard Cut Oxygen
Preheat Oxygen
Preheat Fuel
Triple bevel torch 2 Cut Oxygen TBT 2
Preheat Oxygen TBT 2
Preheat Fuel TBT 2
Triple bevel torch 3 Cut Oxygen TBT 3
Preheat Oxygen TBT 3
Preheat Fuel TBT 3
Triple bevel preheat torch Preheat Oxygen TBPT
Preheat Fuel TBPT
Seitenansicht 273
1 2 ... 269 270 271 272 273 274 275 276 277 278 279 ... 293 294

Kommentare zu diesen Handbüchern

Keine Kommentare