Phoenix 9.76.0 Installation and Setup Manual 806410 179
8 Diagnostics
EDGE Pro Machine Interface Tests
The Phoenix software provides a series of diagnostic tests for the Hypertherm EDGE Pro CNC. These tests require the
following test hardware:
Note:
228510 and 228511 both include the serial, USB, and LAN/Hypernet testers.
If you are using the keyboard-only interface on the CNC (No Touchscreen Installed is selected in the Special
Setups screen) you cannot perform the machine interface tests as described in this section unless you have a
mouse installed on one of the USB ports.
Connector test hardware Kit part number
Serial port 228512
USB port 228512
LAN/HyperNet 228512
Picopath I/O – 1
st
tester (orange stripe)
Picopath I/O – 2
nd
tester (white stripe)
228510
Picopath axes (blue) 228510
Picopath THC (yellow) 228510
HyPath I/O – 1
st
tester (green stripe)
HyPath I/O – 2
nd
tester (red stripe)
228511
HyPath axes (green) 228511
HyPath THC (blue) 228511
Seitenansicht 178